Application: | Construction, Overhead, Underground, Industrial, Power Station |
---|---|
Voltage: | High Voltage Cable |
Current: | AC Cable |
Insulation Material: | XLPE |
Sheath Material: | PVC |
Material Shape: | Round Wire |
Samples: |
---|
Customization: |
---|
Suppliers with verified business licenses
Type | Description | Application Occassion | |
Cu | Al | ||
YJV | YJLV | XLPE insulation PVC sheath power cable | To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn't bear mechanical force outside |
YJY | YJLY | XLPE insulation PE sheath power cable | |
YJV22 | YJLV22 | XLPE insulation, steel tape armor, PVC sheath power cable | To be laid underground, the cable could bear certain mechanical force, but it couldn't bear great pulling force. |
YJV23 | YJLV23 | XLPE insulation, steel tape armor, PE sheath power cable | |
YJV62 | YJLV62 | XLPE insulation, have no the magnetism steel tape armor, PE sheath power cable | |
YJV32 | YJLV32 | XLPE insulation, thin steel-wire armor, PVC sheath power cable | Be applicable to the well, water inside and fall in the bad soil, the cable can bear the equal dint outside the machine with pull the dint |
YJV72 | YJLV72 | XLPE insulation, have no magnetism thick steel-wire armor, PVC sheath power cable | |
YJV42 | YJLV42 | XLPE insulation, thick steel-wire armor, PVC sheath power cable | Be applicable to the well, underwater with the bottom of sea, the cable can bear the bigger pressure with lead to pull the dint. |
Hint Specially |
The single-core magnetism material packs the cable is not suitable to use for AC power supply back track, the necessity hour eligibility uses the single-core 62 or 72 type pack the cable. Disallow the cent to cross the magnetism piping mutually when single-core cable establish, in order to prevent results in the descent that cable transport electric current ability. |
Rated cross area(mm2) | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | |
Cu (Ω/km) |
Non-tinned | 36.0 | 24.5 | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 |
Tinned | 36.7 | 24.8 | 18.2 | 12.2 | 7.56 | 4.70 | 3.11 | 1.84 | |
Al (Ω/km) | / | / | / | 18.1 | 12.1 | 7.42 | 4.61 | 3.08 |
Rated cross area(mm2) | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | |
Cu (Ω/km) |
Non-tinned | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 |
Tinned | 1.16 | 0.734 | 0.529 | 0.391 | 0.270 | 0.195 | 0.154 | 0.126 | |
Al (Ω/km) | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 |
Rated cross area(mm2) | 185 | 240 | 300 | 400 | 500 | 630 | 800 | 1000 | |
Cu (Ω/km) |
Non-tinned | 0.0991 | 0.0754 | 0.0601 | 0.0470 | 0.0366 | 0.0283 | 0.0221 | 0.0176 |
Tinned | 0.100 | 0.0762 | 0.0607 | 0.0475 | 0.0369 | 0.0286 | 0.0224 | 0.0177 | |
Al (Ω/km) | 0.164 | 0.125 | 0.100 | 0.0778 | 0.0605 | 0.0469 | 0.0367 | 0.0291 |
Rated Voltage (kV) |
3.6/6 | 6/6 6/10 |
8.7/10 8.7/15 |
12/20 | 18/30 | 21/35 | 26/35 |
Test Voltage (kV) |
6.23 | 10.38 | 15.05 | 20.76 | 31.14 | 36.33 | 44.98 |
Discharge capacity (Pc) |
10 | 10 | 10 | 10 | 10 | 10 | 10 |
Rated Voltage (kV) |
0.6/1 | 1.8/3 | 3.6/6 3.6/10 |
6/6 6/10 |
8.7/10 8.7/15 |
12/20 | 18/30 | 21/35 | 26/35 |
Test Voltage (kV) |
3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
Test Time (min) |
5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
U0/Um Area mm2 |
0.6/1 | 1.8/3 | 3.6/6 3.6/10 |
6/6 6/10 |
8.7/10 8.7/15 |
12/20 | 18/30 | 21/35 | 26/35 |
Core No | 1 | 4-400 | 25-500 | 25-500 | 35-500 | 35-500 | 50-500 | 50-500 | 50-500 |
2 | 2.5-185 | / | / | / | / | / | / | / | |
3 | 2.5-300 | 25-500 | 25-500 | 35-500 | 35-500 | 50-500 | 50-500 | 50-500 | |
3+1 | 2.5-300 | / | / | / | / | / | / | / | |
4 | 2.5-300 | / | / | / | / | / | / | / | |
3+2 | 2.5-240 | / | / | / | / | / | / | / | |
4+1 | 2.5-300 | / | / | / | / | / | / | / | |
5 | 2.5-95 | / | / | / | / | / | / | / |